Fire Alarm Input and Output Modules for Warehouses | Wanlin Fire · Practical Product and Application Information
Wanlin Fire C
Explore products, technical articles, FAQs, and application information related to Wanlin Fire C from Fire Alarm Input and Output Modules for Warehouses | Wanlin Fire.
Products and Services
Review relevant products, system options, application guidance, project support, and pre-sales or after-sales services.
Information for Selection
Compare the application scenario, functional requirements, installation environment, interfaces, communication method, quantity, and project schedule.
How Information Is Verified
Confirm model numbers, technical parameters, certifications, delivery terms, and compatibility against current product documents and agreed project requirements.
-
Fire alarm export license for Greece Buyers: Smart Fire Safe···
Fire alarm export lice···
2026-09-01
Wanlin Fire - China source manufacturer for fire alarm export license. Featured model WL-TH-SD (Photoelectric Smoke Detector): Photoelectric, low-current scattering chamber; EN54-7 Class A2, alarm at 0.11-0.14 dB/m obscuration; Built-in 85 dB at 3 m sounder + NO/NC relay contact; -10 to +50 deg C, 0-93% RH (tropical humidity rated). Full lineup: smoke and he···
-
Dual path communicator for Brazil Buyers: Smart Fire Safety ···
Dual path communicator···
2026-09-01
Wanlin Fire - China source manufacturer for dual path communicator. Featured model WL-TH-SD (Photoelectric Smoke Detector): Dual-sensor: photoelectric + 57 deg C thermal backup; EN54-7 Class A3, alarm at 0.13-0.17 dB/m obscuration; Built-in 88 dB at 3 m sounder + NO/NC relay contact; -10 to +55 deg C, 0-95% RH (tropical humidity rated). Full lineup: smoke an···
-
Nursery smoke detector for Peru Buyers: Smart Fire Safety Ex···
Nursery smoke detector···
2026-09-01
Wanlin Fire - China source manufacturer for nursery smoke detector. Featured model WL-TH-SD (Photoelectric Smoke Detector): Photoelectric, low-current scattering chamber; EN54-7 Class A2, alarm at 0.11-0.14 dB/m obscuration; Built-in 85 dB at 3 m sounder + NO/NC relay contact; -10 to +50 deg C, 0-93% RH (tropical humidity rated). Full lineup: smoke and heat ···
-
Long battery life fire detector for Slovakia Buyers: Smart F···
Long battery life fire···
2026-09-01
Wanlin Fire - China source manufacturer for long battery life fire detector. Featured model WL-TH-SD (Photoelectric Smoke Detector): Photoelectric, 850 nm infrared scattering chamber; EN54-7 Class A2, alarm at 0.10-0.13 dB/m obscuration; Built-in 85 dB at 3 m sounder + NO/NC relay contact; -10 to +50 deg C, 0-95% RH (tropical humidity rated). Full lineup: sm···
-
Combination sounder strobe for South Korea Buyers: Smart Fir···
Combination sounder st···
2026-09-01
Wanlin Fire - China source manufacturer for combination sounder strobe. Featured model WL-TH-SD (Photoelectric Smoke Detector): Dual-sensor: photoelectric + 57 deg C thermal backup; EN54-7 Class A3, alarm at 0.13-0.17 dB/m obscuration; Built-in 88 dB at 3 m sounder + NO/NC relay contact; -10 to +55 deg C, 0-95% RH (tropical humidity rated). Full lineup: smok···
-
Ultra-low power fire sensor for Chile Buyers: Smart Fire Saf···
Ultra-low power fire s···
2026-09-01
Wanlin Fire - China source manufacturer for ultra-low power fire sensor. Featured model WL-TH-SD (Photoelectric Smoke Detector): Photoelectric, low-current scattering chamber; EN54-7 Class A2, alarm at 0.11-0.14 dB/m obscuration; Built-in 85 dB at 3 m sounder + NO/NC relay contact; -10 to +50 deg C, 0-93% RH (tropical humidity rated). Full lineup: smoke and ···
-
Thailand power plant fire alarm for Turkey Buyers: Smart Fir···
Thailand power plant f···
2026-09-01
Wanlin Fire - China source manufacturer for Thailand power plant fire alarm. Featured model WL-TH-SD (Photoelectric Smoke Detector): Photoelectric, 850 nm infrared scattering chamber; EN54-7 Class A2, alarm at 0.10-0.13 dB/m obscuration; Built-in 85 dB at 3 m sounder + NO/NC relay contact; -10 to +50 deg C, 0-95% RH (tropical humidity rated). Full lineup: sm···
-
residential fire protection solution: Trusted Export Supplie···
residential fire prote···
2026-08-20
Wanlin Fire Control by Wanlin Manufacturing Group - China's leading source manufacturer of residential fire protection solution. EN 14604 / EN 54 certified smart fire safety products, OEM/ODM, factory direct. Contact +8613261677119.
-
Hochiki smoke detector competitor: OEM ODM Supply from Wanli···
Hochiki smoke detector···
2026-08-20
Wanlin Fire Control by Wanlin Manufacturing Group - China's leading source manufacturer of Hochiki smoke detector competitor. EN 14604 / EN 54 certified smart fire safety products, OEM/ODM, factory direct. Contact +8613261677119.
-
DIN VDE 0833 fire alarm: Wholesale Supply from China Source ···
DIN VDE 0833 fire alar···
2026-08-20
Wanlin Fire Control by Wanlin Manufacturing Group - China's leading source manufacturer of DIN VDE 0833 fire alarm. EN 14604 / EN 54 certified smart fire safety products, OEM/ODM, factory direct. Contact +8613261677119.

